Filtration units are used for separation of waste material from woodworking technology. Steel galvanized structure is equipped by filter hoses from high quality polyester material. Separated waste material falls down into steel containers. Modular design allows multiply capacity. Each module has own vibration motor for filter regeneration. According to ventilator and filter unit arrangement we can divide filtration units to:
In overpressure arrangement is ventilator installed prior to filter unit. Air with extracted waste material is transported to filter unit through ventilator. Filter regeneration is provided by stopped ventilator.
Basic equipment of FJ module
Filtration units FJ are delivered in opened and closed design, closed design can be installed outside the building and filtered air can be returned back into working area.
Advantages
Closed type contains in addition
Ventilator is not a part of filter unit.
For filter units we can offer ventilators FAN 403, FAN 600, FAN 800 or FAN 1000 according to extraction requirements.
Open type with steel containers for waste
type | filtrating area
m2 |
containers volume
l |
width
mm B |
length
mm L |
height
mm H |
Inlet diameter
mm |
capacity
m3/hod |
FJ 45-3B | 45 | 3 x 150 | 1250 | 2750 | 3742 | 300 | 4500 |
FJ 60-3B | 60 | 3 x 150 | 1250 | 2750 | 4242 | 300 | 6000 |
FJ 75-3B | 75 | 3 x 150 | 1250 | 2750 | 4742 | 350 | 7500 |
FJ 90-3B | 90 | 3 x 150 | 1250 | 2750 | 5242 | 350 | 9000 |
FJ 78-4B | 78 | 4 x 150 | 1254 | 3344 | 4242 | 350 | 7800 |
FJ 98-4B | 98 | 4 x 150 | 1254 | 3344 | 4742 | 400 | 10000 |
FJ 117-4B | 117 | 4 x 150 | 1254 | 3344 | 5242 | 400 | 11700 |
FJ 120-6B | 120 | 6 x 150 | 1250 | 4750 | 4242 | * | 12000 |
FJ 150-6B | 150 | 6 x 150 | 1250 | 4750 | 4742 | * | 15000 |
FJ 180-6B | 180 | 6 x 150 | 1250 | 4750 | 5242 | * | 18000 |
FJ 160-8B | 160 | 8 x 150 | 1254 | 5938 | 4242 | * | 16000 |
FJ 200-8B | 200 | 8 x 150 | 1254 | 5938 | 4742 | * | 20000 |
FJ 240-8B | 240 | 8 x 150 | 1254 | 5938 | 5242 | * | 24000 |
*inlet diameter has to be stated individually
Closed type with steel containers for waste
type | filtrating area
m2 |
containers volume
l |
width
mm B |
length
mm L |
height
mm H |
Inlet
mm |
capacity
m3/hod |
FJ 45-3BO | 45 | 3 x 150 | 1250 | 2750 | 4537 | 300 | 4500 |
FJ 60-3BO | 60 | 3 x 150 | 1250 | 2750 | 4937 | 300 | 6000 |
FJ 75-3BO | 75 | 3 x 150 | 1250 | 2750 | 5337 | 350 | 7500 |
FJ 90-3BO | 90 | 3 x 150 | 1250 | 2750 | 5737 | 350 | 9000 |
FJ 78-4BO | 78 | 4 x 150 | 1254 | 3344 | 4937 | 350 | 7800 |
FJ 98-4BO | 98 | 4 x 150 | 1254 | 3344 | 5337 | 400 | 10000 |
FJ 117-4BO | 117 | 4 x 150 | 1254 | 3344 | 5737 | 400 | 11700 |
FJ 120-6BO | 120 | 6 x 150 | 1250 | 4750 | 4937 | * | 12000 |
FJ 150-6BO | 150 | 6 x 150 | 1250 | 4750 | 5337 | * | 15000 |
FJ 180-6BO | 180 | 6 x 150 | 1250 | 4750 | 5737 | * | 18000 |
FJ 160-8BO | 160 | 8 x 150 | 1254 | 5938 | 4937 | * | 16000 |
FJ 200-8BO | 200 | 8 x 150 | 1254 | 5938 | 5337 | * | 20000 |
FJ 240-8BO | 240 | 8 x 150 | 1254 | 5938 | 5737 | * | 24000 |
*inlet diameter has to be stated individually